What sets HARPIA apart? It's the flexibility! This system is built around the HARPIA-TA transient absorption spectrometer, but it's not a one-trick pony. You can easily add time-correlated single-photon counting, Kerr gate, or fluorescence upconversion modules to boost your capabilities. And with third beam delivery and microscopy options, you'll be able to tackle even the toughest experiments. Plus, HARPIA's designed for seamless switching between measurement modes, so you can work efficiently and effectively. And to top it all off, each module is housed in a sturdy, monolithic aluminum body for maximum optical stability and minimal optical path lengths. Pair HARPIA with a PHAROS or CARBIDE laser, and ORPHEUS series OPAs for a single-supplier solution that simplifies your workflow.
Transient Absorption, Pump - Probe (HARPIA - TA) :
Configuration | UV-VIS | UV-VIS-NIR | MIR |
Probe spectral range | 350 – 1100 nm | 350 – 1600 nm | 2000 – 13000 nm |
Pump range | 240 – 2200 nm | 450 – 2200 nm *(1) | |
Delay range (resolution) | 8 ns (8.3 fs) | 4 ns (4.2 fs) | |
Temporal resolution | ≤ laser pulse duration or better | ||
Laser repetition rate | 1 – 100 kHz | ||
Maximum data acquisition rate | 3850 Hz | Laser repetition rate | |
Modes | Reflection and transmission |
Flash Photolysis - Nanosecond Transient Absorption (HARPIA - TA - FP) :
Module | HARPIA-TA-FP | HARPIA-TA-FP-UV | ||
HARPIA-TA configuration | UV-VIS | UV-VIS-NIR | UV-VIS | UV-VIS-NIR |
Probe spectral range | 450 – 1100 nm | 450 – 1600 nm | 350 – 1100 nm | 350 – 1600 nm |
Pump range | 240 – 2200 nm | |||
Delay range | up to 8 ms | up to 500 μs | ||
Delay resolution | 100 ps | |||
Temporal resolution | 2 ns | 1 ns | ||
Probe laser repetition rate | 1850 Hz | |||
Maximum data acquisition rate | 3850 Hz | |||
Mode | Reflection and transmission |
Kerr gate, Fluorescence Upconversion, and TCSPC (HARPIA-TF) :
Module | HARPIA-TF | ||
Measurement technique | Kerr gate | Fluorescence upconversion | TCSPC |
Spectral range | 250 – 1100 nm | 330 – 820 nm | 220 – 820 nm *(1) |
Pump range | 240 – 2200 nm | ||
Temporal resolution | 400 – 500 fs | ≤ laser pulse duration or better | < 180 ps or < 50 ps |
Max measurement range | 8 ns | 5 μs | |
Delay resolution | 8.3 fs | n/a | |
Gate (probe) beam requirements | 25 – 30 μJ | n/a | |
Compatible with | TCSPC | Kerr gate or fluorescence upconversion | |
Modes | Transmission |
FSRS, Multi-pulse time-resolved transient absorption (HARPIA-TB) :
Module | HARPIA-TB | |
Pump for multi-pulse experiments | NIR probe | |
Acceptable wavelength range | 450 – 2200 nm *(1) | 1600 – 2600 nm |
Delay range (resolution) | 4 ns (4.2 fs) | |
Modes | Transmission |
Transient absorption and Reflection microscopy (HARPIA-MM) :
Module | HARPIA-MM | |
Spatial resolution *(1) | monochromatic | polychromatic |
< 2 µm | < 10 µm | |
Probe spectral range | 460 – 1100 nm | |
Pump range | 240 – 700 nm | |
Temporal resolution | 500 fs | |
Maximum working distance *(2) | 13 mm | |
Sample motion range | 13 × 13 × 13 mm | |
Modes | Reflection and transmission |
Dimensions :
Model | Physical dimensions (L × W × H) *(1) |
HARPIA-TA | 730 × 420 × 183 mm |
HARPIA-TA Sample chamber area (L × W) |
205 × 216 mm |
HARPIA-TF | 571 × 275 × 183 mm |
HARPIA-TB | 670 × 252 × 183 mm |
HARPIA Complete Ultrafast Spectroscopy System (pdf / English)
Examples of Ultrafast Spectroscopy Applications (pdf / English)