Light Conversion |HARPIA
  • Home
  • Light Conversion |HARPIA

HARPIA

Complete Ultrafast Spectroscopy System
Meet HARPIA, the ultimate ultrafast spectroscopy system! This powerhouse is designed to deliver a wide range of sophisticated time-resolved spectroscopic measurements in a compact and user-friendly package. With an intuitive interface and easy maintenance, it's the perfect solution for today's scientific applications. Whether you need to customize or expand your setup, HARPIA's got you covered!

Light Conversion |HARPIA

What sets HARPIA apart? It's the flexibility! This system is built around the HARPIA-TA transient absorption spectrometer, but it's not a one-trick pony. You can easily add time-correlated single-photon counting, Kerr gate, or fluorescence upconversion modules to boost your capabilities. And with third beam delivery and microscopy options, you'll be able to tackle even the toughest experiments. Plus, HARPIA's designed for seamless switching between measurement modes, so you can work efficiently and effectively. And to top it all off, each module is housed in a sturdy, monolithic aluminum body for maximum optical stability and minimal optical path lengths. Pair HARPIA with a PHAROS or CARBIDE laser, and ORPHEUS series OPAs for a single-supplier solution that simplifies your workflow.


Features :
  • Excellent performance at a high repetition rate
  • Measurement range from UV to MIR
  • Market-leading sensitivity
  • Modules for time-resolved, and multi-pulse experiments
  • High-level automation in a compact footprint


Applications :
  • Transient absorption and reflection in bulk and microscopy
  • Multi-pulse transient absorption in transmission
  • Time resolved fluorescence: Femtosecond fluorescence upconversion, Kerr gate, TCSPC
  • Femtosecond stimulated Raman scattering (FSRS)
  • Intensity-dependent transient absorption and reflection
  • Flash photolysis – nanosecond transient absorption


Processes Explored by ultrafast Spectrocopy :
  • Charge transfer (electron, proton)
  • Solvation
  • Vibrational relaxation
  • Exciton energy transfer
  • Photoreaction dynamics


Specifications :

Transient Absorption, Pump - Probe (HARPIA - TA) :

Configuration UV-VIS UV-VIS-NIR MIR
Probe spectral range 350 – 1100 nm 350 – 1600 nm 2000 – 13000 nm
Pump range 240 – 2200 nm 450 – 2200 nm *(1)
Delay range (resolution) 8 ns (8.3 fs) 4 ns (4.2 fs)
Temporal resolution ≤ laser pulse duration or better
Laser repetition rate 1 – 100 kHz
Maximum data acquisition rate 3850 Hz Laser repetition rate
Modes Reflection and transmission
  1. *Wavelength range is configurable to 240 – 700 nm


Flash Photolysis - Nanosecond Transient Absorption (HARPIA - TA - FP) :

Module HARPIA-TA-FP HARPIA-TA-FP-UV
HARPIA-TA configuration UV-VIS UV-VIS-NIR UV-VIS UV-VIS-NIR
Probe spectral range 450 – 1100 nm 450 – 1600 nm 350 – 1100 nm 350 – 1600 nm
Pump range 240 – 2200 nm
Delay range up to 8 ms up to 500 μs
Delay resolution 100 ps
Temporal resolution 2 ns 1 ns
Probe laser repetition rate 1850 Hz
Maximum data acquisition rate 3850 Hz
Mode Reflection and transmission


Kerr gate, Fluorescence Upconversion, and TCSPC (HARPIA-TF) :

Module HARPIA-TF
Measurement technique Kerr gate Fluorescence upconversion TCSPC
Spectral range 250 – 1100 nm 330 – 820 nm 220 – 820 nm *(1)
Pump range 240 – 2200 nm
Temporal resolution 400 – 500 fs ≤ laser pulse duration or better < 180 ps or < 50 ps
Max measurement range 8 ns 5 μs
Delay resolution 8.3 fs n/a
Gate (probe) beam requirements 25 – 30 μJ n/a
Compatible with TCSPC Kerr gate or fluorescence upconversion
Modes Transmission
  1. *Spectral range is extendable with an additional NIR detector (measurement range 1000 – 1700 nm)


FSRS, Multi-pulse time-resolved transient absorption (HARPIA-TB) :

Module HARPIA-TB
  Pump for multi-pulse experiments NIR probe
Acceptable wavelength range 450 – 2200 nm *(1) 1600 – 2600 nm
Delay range (resolution) 4 ns (4.2 fs)
Modes Transmission
  1. *Wavelength range is configurable to 240 – 700 nm


Transient absorption and Reflection microscopy (HARPIA-MM) :

Module HARPIA-MM
Spatial resolution *(1) monochromatic polychromatic
  < 2 µm < 10 µm
Probe spectral range 460 – 1100 nm
Pump range 240 – 700 nm
Temporal resolution 500 fs
Maximum working distance *(2) 13 mm
Sample motion range 13 × 13 × 13 mm
Modes Reflection and transmission
  1. *White light generation has axial color at focus and wavelength-dependent mode size and NA. Focused white light will exhibit focus shift and spot size variation depending on the chosen spectral range. Polychromatic spot size is given at full spectral range, monochromatic is at 500 nm with a 10 nm bandwidth.
  2. *Depends on the objective used


Dimensions :

Model Physical dimensions (L × W × H) *(1)
HARPIA-TA 730 × 420 × 183 mm
HARPIA-TA
Sample chamber area (L × W)
205 × 216 mm
HARPIA-TF 571 × 275 × 183 mm
HARPIA-TB 670 × 252 × 183 mm
  1. *Without external spectrograph


Brochures & Datasheets :

   HARPIA Complete Ultrafast Spectroscopy System (pdf / English)

   Examples of Ultrafast Spectroscopy Applications (pdf / English)